Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Fisioter. Mov. (Online) ; 35: e35125, 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1384950

RESUMO

Abstract Introduction: A prolonged assisted ventilation (AV) period might induce complications. Objective: To compare functional capacities and muscle strength of patients under AV. Methods: This is a prospective cohort observational study. The patients selected were under mechanical ventilation in any given moment, and they were evaluated only at the time of discharge from the intensive care unit (ICU). The convenience sample of 103 was selected and divided into a group with up to six days of AV (G6) and another with seven days or more of AV (G7). The protocol proposed was: application of the Medical Research Council (MRC) scale, dynamometry, Barthel index, ability to ambulate at ICU discharge. A call was made to the patients six and 12 months after hospital discharge for the application of the Barthel index. Results: We verified that G6 patients obtained better muscular strength measured through right 14 (8-30) and left 18 (8-26) dynamometry and MRC scale 48 (44-56). Only seven (14%) patients from the G7 group were able to ambulate. G7 patients showed greater functional loss at hospital discharge 32 (15-60). After one year of hospital discharge, both groups had recovered their functional capacity 100 (100-100). Conclusion: When evaluating the process of AV, it is possible to conclude that the longer the ventilator is used, the greater the loss of strength and functionality. In addition, there is a significant recovery of functionality after one year of hospital discharge.


Resumo Introdução: Um período prolongado de ventilação assistida (VA) pode induzir complicações. Objetivo: Comparar as capacidades funcionais e a força muscular de pacientes sob VA. Métodos: Trata-se de um estudo observacional de coorte prospectivo. Os pacientes selecionados encontravam-se em ventilação mecânica em qualquer momento, sendo avaliados apenas no momento da alta da unidade de terapia intensiva (UTI). A amostra de conveniência de 103 foi selecionada e dividida em um grupo com até seis dias de VA (G6) e outro com sete dias ou mais de VA (G7). O protocolo proposto foi: aplicação da escala MRC, dinamometria, índice de Barthel, capacidade de deambulação na alta da UTI. Foi feito um chamado aos pacientes seis e 12 meses após a alta hospitalar para aplicação do índice de Barthel. Resultados: Verificamos que os pacientes do G6 obtiveram melhor força muscular medida através da dinamometria direita 14 (8-30) e esquerda 18 (8-26) e escala do MRC 48 (44-56). Apenas sete (14%) pacientes do grupo G7 conseguiram deambular. Os pacientes do G7 apresentaram maior perda funcional na alta hospitalar 32 (15-60). Após um ano da alta hospitalar, ambos os grupos recuperaram sua capacidade funcional 100 (100-100). Conclusão: Ao avaliar o processo de AV, é possível concluir que quanto maior o tempo de uso do ventilador, maior a perda de força e funcionalidade. Além disso, há uma recuperação significativa da funcionalidade após um ano da alta hospitalar.


Assuntos
Humanos , Respiração Artificial , Debilidade Muscular , Força Muscular , Unidades de Terapia Intensiva , Ventiladores Mecânicos , Mortalidade , Sobrevivência
2.
São Paulo med. j ; 135(3): 302-308, May-June 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-904072

RESUMO

ABSTRACT CONTEXT: Today, through major technological advances in diagnostic resources within medicine, evaluation and monitoring of clinical parameters at the patient's bedside in intensive care units (ICUs) has become possible. CASE REPORT: This case report presents results and interpretations from predictive mechanical ventilation weaning indexes obtained through monitoring using chest electrical bioimpedance tomography. These indexes included maximum inspiratory pressure, maximum expiratory pressure, shallow breathing index and spontaneous breathing test. These were correlated with variations in tidal volume variables, respiratory rate, mean arterial pressure and peripheral oxygen saturation. Regarding the air distribution behavior in the pulmonary parenchyma, the patient showed the pendelluft phenomenon. Pendelluft occurs due to the time constant (product of the airways resistance and compliance) asymmetry between adjacent lung. CONCLUSION: Bioelectrical impedance tomography can help in weaning from mechanical ventilation, as in the case presented here. Pendelluft was defined as a limitation during the weaning tests.


RESUMO CONTEXTO: Atualmente, com o grande avanço tecnológico em recursos para diagnósticos em medicina, a avaliação e a monitorização de parâmetros clínicos à beira leito de paciente em unidade de terapia intensiva (UTI) se tornou possível. RELATO DE CASO: Neste relato de caso, apresentam-se os resultados e a interpretação de índices preditivos de desmame da ventilação mecânica obtidos pela tomografia de bioimpedância elétrica torácica. Esses índices incluíram a pressão inspiratória máxima, pressão expiratória máxima, índice de respiração superficial e teste de respiração espontânea. Estes estavam correlacionados com as variações de volume corrente, frequência respiratória, pressão arterial média e saturação periférica de oxigênio. Quanto ao comportamento da distribuição de ar no parênquima pulmonar, o paciente apresentou o fenômeno pendelluft. O pendelluft ocorre dado pela constante de tempo (produto da resistência e complacência das vias aéreas) de forma assimétrica entre as unidades pulmonares adjacentes. CONCLUSÃO: A tomografia de bioimpedância pode auxiliar no desmame da ventilação mecânica, como no caso apresentado. Pendelluft foi definido como limitação durante a execução dos testes para desmame.


Assuntos
Humanos , Feminino , Idoso , Tomografia/métodos , Desmame do Respirador/métodos , Troca Gasosa Pulmonar/fisiologia , Impedância Elétrica , Sistemas Automatizados de Assistência Junto ao Leito , Pulmão/fisiopatologia , Valores de Referência , Respiração Artificial/efeitos adversos , Testes de Função Respiratória , Fatores de Tempo , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
3.
Sao Paulo Med J ; 135(3): 302-308, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28380204

RESUMO

CONTEXT:: Today, through major technological advances in diagnostic resources within medicine, evaluation and monitoring of clinical parameters at the patient's bedside in intensive care units (ICUs) has become possible. CASE REPORT:: This case report presents results and interpretations from predictive mechanical ventilation weaning indexes obtained through monitoring using chest electrical bioimpedance tomography. These indexes included maximum inspiratory pressure, maximum expiratory pressure, shallow breathing index and spontaneous breathing test. These were correlated with variations in tidal volume variables, respiratory rate, mean arterial pressure and peripheral oxygen saturation. Regarding the air distribution behavior in the pulmonary parenchyma, the patient showed the pendelluft phenomenon. Pendelluft occurs due to the time constant (product of the airways resistance and compliance) asymmetry between adjacent lung. CONCLUSION:: Bioelectrical impedance tomography can help in weaning from mechanical ventilation, as in the case presented here. Pendelluft was defined as a limitation during the weaning tests.


Assuntos
Impedância Elétrica , Pulmão/fisiopatologia , Sistemas Automatizados de Assistência Junto ao Leito , Troca Gasosa Pulmonar/fisiologia , Tomografia/métodos , Desmame do Respirador/métodos , Idoso , Feminino , Humanos , Valor Preditivo dos Testes , Valores de Referência , Reprodutibilidade dos Testes , Respiração Artificial/efeitos adversos , Testes de Função Respiratória , Fatores de Tempo
4.
J. health sci. (Londrina) ; 19(2)30/04/2017.
Artigo em Português | LILACS | ID: biblio-847532

RESUMO

Objetivo do estudo foi comparar o sistema fechado de aspiração (SFA) com o sistema aberto de aspiração (SAA) e, para cada sistema, comparar variáveis hemodinâmicas e respiratórias para cada um dos momentos. Incluídos pacientes adultos, em ventilação mecânica em pós-operatório eletivo. Variáveis registradas pré-coleta, 15 e 30 minutos após a adaptação do SFA, imediatamente, após a oxigenação pós-aspiração com SFA, nos minutos 6, 16, 31 e 61 após aspiração com o SFA. O mesmo processo foi repetido para o SAA. Foram incluídos quarenta pacientes. Quando comparado o momento imediato a pós-oxigenação com o momento 6 minutos após a aspiração foi encontrado aumento da frequência cardíaca (FC) (p = 0,04), diminuição (p= 0,034) com o momento 31 minutos e diminuição (p= 0,032) com o momento 61 minutos. Observou-se que a FC teve diminuição significativa, em todos os momentos analisados após a aspiração, comparando com o momento imediato pós-oxigenação, no SAA. Também foi evidenciado aumento (p=0,03) no valor de volume corrente (VT), quando comparado o momento 31 minutos do SFA com o SAA. Conclusão: Apesar de apresentar alterações significativas, em algumas variáveis, quando comparados os sistemas, as modificações se mantiveram dentro da normalidade e retornaram ao valor basal em uma hora após a aspiração. (AU)


The goal was to compare the closed suction system - CSS to the open suction system - OSS and, for each system, compare hemodynamic and respiratory parameters in different moments. The group was comprised of mechanically ventilated adult patients in pos operatory period. Variables were recorded before CSS adaptation, 15 and 30 minutes after CSS adaptation , immediately after post-oxygenation aspiration with CSS, 6, 16, 31 and 61 minutes after aspiration with CSS. The same process was repeated for the OSS. Forty patients were included. When compared the post-oxygenation increased heart rate was found (p=0,04) to the 6 minutes after CSS, decreased heart rate after 31 minutes (p=0.034) and 61 minutes (p=0,032) after CSS. It was observed that the HR was significantly reduced at all times examined after aspiration, compared to the time immediately post-oxygenation for the OSS. It was also demonstrated an increase (p = 0.03) in the amount of tidal volume (TV), when CSS was compared to the OSS 31 minutes after suction. Despite showing significant changes in some variables, it remained within the normal range and returned to baseline one hour after suction. (AU)

5.
Rev. bras. promoç. saúde (Impr.) ; 29(1): 107-116, jan.-mar.2016.
Artigo em Inglês, Português | LILACS | ID: biblio-827410

RESUMO

Objetivo: Caracterizar a natureza e frequência das infecções pulmonares em pacientes adultos pós-transplantados renais tardios. Métodos: Foi realizado um estudo de revisão bibliográfica nas seguintes bases de dados eletrônicas: PubMed, Scielo e Web of Science. Os critérios de elegibilidade do estudo foram: artigos publicados entre os anos de 2010 e 2015, nos idiomas inglês, português ou espanhol, do tipo: ensaios clínicos, randomizados ou não, estudos de caso-controle, estudos de coorte e estudos longitudinais em humanos. Foram excluídos os artigos cujos participantes da pesquisa fossem menores de 18 anos de idade, além dos artigos duplicados em mais de uma das bases de dados. As palavras-chave utilizadas e combinadas na pesquisa foram: pneumonia, infecção pulmonar, infecção, transplante renal, hospitalização. Resultados: Os agentes etiológicos mais incidentes são Pneumocystis jirovecii, Mycobacterium tuberculosis e Aspergillus fumigatus. As infecções pulmonares são devidas, em grande número, ao regime imunossupressor, tempo prolongado de hemodiálise, disfunção de enxerto e transmissão inter humana. Frequentemente, essas infecções evoluem com dispneia progressiva e insuficiência respiratória aguda, sendo necessária ventilação mecânica invasiva ou não invasiva. Conclusão: As evidências científicas apontam uma alta prevalência de infecções pulmonares nos pacientes transplantados renais.


Objective: The aim of this study was to characterize the nature and frequency of pulmonary infections in late post-kidney transplant adult recipients. Methods: A bibliographic review was conducted in the following electronic databases: PubMed, SciELO and Web of Science. The study eligibility criteria were articles published between the years 2010 and 2015, in English, Portuguese or Spanish, comprising clinical trials, randomized or not, case-control studies, cohort studies, and longitudinal studies in humans. Articles whose research subjects were aged under 18 years were excluded, as well as repeated articles, which appeared in more than one of the databases. The keywords used and combined in the research were: pneumonia, lung infection, infection, kidney transplantation, hospitalization. Results: The most common etiological agents are Pneumocystis jirovecii, Mycobacterium tuberculosis and Aspergillus fumigatus. Pulmonary infections are, in a large number, due to the immunosuppressive regimen, extensive length of time on hemodialysis, graft dysfunction and interhuman transmission. Often, such infections evolve with progressive dyspnea and acute respiratory failure, thus requiring invasive or non-invasive mechanical ventilation. Conclusion: The evidences point out a high prevalence of pulmonary infections in kidney transplant recipients.


Objetivo: El objetivo del estudio fue caracterizar la naturaleza y la frecuencia de las infecciones pulmonares de pacientes adultos pos trasplante renal tardío. Métodos: Se realizó um estudio de revisión bibliográfica en las siguientes bases de datos electrónicas: PubMed, Scielo y Web of Science. Los criterios de elegibilidad del estudio fueron: artículos publicados entre los años de 2010 y 2015 en los idiomas inglés, portugués o español, del tipo ensayos clínicos randomizados o no, estudios de casocontrol, estudios de cohorte y estudios longitudinales en humanos. Fueron excluidos los artículos cuyos los participantes de la investigación tenían menos de 18 años de edad, además de los artículos repetidos en más de una base de datos. Las palabrasclave utilizadas y asociadas en la investigación fueron: neumonía, infección pulmonar, infección, trasplante renal, hospitalización. Resultados: Los agentes etiológicos más incidentes son la Pneumocystis jirovecii, el Mycobacterium tuberculosis y el Aspergillus fumigatus. Las infecciones pulmonares son causadas, en su mayoría, por el régimen inmunosupresor, el largo tiempo de hemodiálisis, la disfunción del injerto y la trasmisión inter humanos. Esas infecciones evolucionan, con frecuencia, com disnea progresiva e insuficiencia respiratoria aguda y la necesidad de ventilación mecánica invasiva o no invasiva. Conclusión: Las evidencias científicas apuntan elevada prevalencia de infecciones pulmonares en los pacientes trasplantados renales.


Assuntos
Humanos , Infecções Respiratórias , Transplante de Rim , Hospital Dia
6.
Sci. med. (Porto Alegre, Online) ; 26(1): 22678, jan-mar 2016. graf.
Artigo em Português | LILACS | ID: biblio-836864

RESUMO

OBJETIVOS: Comparar valores de pressão inspiratória máxima (PImáx) aferidos por um manovacuômetro digital e por um dispositivo eletrônico de treinamento muscular inspiratório e avaliar as repercussões hemodinâmicas após as medidas. MÉTODOS: A amostra foi composta por indivíduos acima de 18 anos, de ambos os sexos, internados na unidade de terapia intensiva, hemodinamicamente estáveis, sem uso de drogas vasoativas ou de sedação, intubados ou traqueostomizados, em processo de desmame da ventilação mecânica. Foram feitas três medidas de PImáx pelos dois equipamentos, com tempo de oclusão de 20 segundos e tempo entre as medidas de cinco minutos. Foram analisados frequência respiratória, pressão arterial média e frequência respiratória antes e após cada medida para cada equipamento utilizado. A análise estatística usou os programas Statistical Analysis System e R Project for Statistical Computing V. 3.1.2, aplicando os testes ANOVA e Wilcoxon. RESULTADOS: Foram incluídos no estudo 58 pacientes. A média das PImáx obtidas com o manovacuômetro digital foi -46,22 centímetros de água (cmH2O), enquanto a média obtida com o dispositivo de TMI foi -13,15 cmH2O (p<0,001). A frequência cardíaca apresentou aumento na comparação antes e após todas as medidas em ambos os dispositivos (p<0,0001). A pressão arterial média apresentou diferença estatisticamente significativa somente entre antes e após a primeira medida obtida pelo manovacuômetro digital, e entre antes e após a segunda medida obtida com o dispositivo de treinamento muscular inspiratório (p<0,001). A frequência respiratória apresentou variação significativa entre antes e após as três medidas em ambos dispositivos (p<0,0001). Os valores das variáveis hemodinâmicas após as medidas de PImáx permaneceram dentro dos limites da normalidade. CONCLUSÕES: O manovacuômetro digital registrou uma PImáx superior à registrada pelo dispositivo eletrônico de treinamento muscular inspiratório. Ambos os dispositivos alteraram os valores das variáveis hemodinâmicas, que entretanto permaneceram dentro da normalidade e sem repercussão clínica.


AIMS: To compare maximum inspiratory pressure (MIP) measured by a digital manometer and by an inspiratory muscle training (IMT) device and to evaluate hemodynamic changes after measurements. METHODS: The sample included male and female individuals older than 18 years admitted to an intensive care unit who were hemodynamically stable, not being treated with vasoactive drugs or sedated, intubated or tracheostomized, and who were in the process of being weaned from mechanical ventilation. MIP was measured by both devices on three different occasions, with an occlusion time of 20 seconds and a 5-minute interval between measurements. The following parameters were assessed: respiratory rate, mean arterial pressure, and respiratory rate before and after each measurement by each device. The statistical analysis was made in the Statistical Analysis System and the R Project for Statistical Computing V. 3.1.2 softwares, using the ANOVA and the Wilcoxon tests. RESULTS: Fifty-eight patients were included in the study. The mean value obtained for MIP was -46.22 centimeters of water (cmH2O) in the digital manometer and -13.15 cmH2O (p<0.001) in the IMT device. Heart rate showed a significant increase (p<0.0001) both before and after all measurements in both devices. Mean arterial pressure showed a statistically significant difference only before and after the first measurement by the digital manometer and before and after the second measurement by the IMT device (p<0.001). The respiratory rate oscillated significantly before and after the three measurements by both devices (p<0.0001). The hemodynamic parameters remained within reference values after MIP measurements. CONCLUSIONS: The digital manometer recorded a higher MIP than that measured by the IMT device. The hemodynamic parameter values oscillated in both devices, but they remained within the normal range and were not clinically significant.


Assuntos
Humanos , Masculino , Feminino , Respiração Artificial , Insuficiência Respiratória , Doenças Respiratórias , Desmame do Respirador , Pressões Respiratórias Máximas , Unidades de Terapia Intensiva
7.
Rev Bras Cir Cardiovasc ; 30(1): 24-32, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25859864

RESUMO

OBJECTIVE: A retrospective cohort study was preformed aiming to verify the presence of transient dysfunction of gas exchange in the postoperative period of cardiac surgery and determine if this disorder is linked to cardiorespiratory events. METHODS: We included 942 consecutive patients undergoing cardiac surgery and cardiac procedures who were referred to the Intensive Care Unit between June 2007 and November 2011. RESULTS: Fifteen patients had acute respiratory distress syndrome (2%), 199 (27.75%) had mild transient dysfunction of gas exchange, 402 (56.1%) had moderate transient dysfunction of gas exchange, and 39 (5.4%) had severe transient dysfunction of gas exchange. Hypertension and cardiogenic shock were associated with the emergence of moderate transient dysfunction of gas exchange postoperatively (P=0.02 and P=0.019, respectively) and were risk factors for this dysfunction (P=0.0023 and P=0.0017, respectively). Diabetes mellitus was also a risk factor for transient dysfunction of gas exchange (P=0.03). Pneumonia was present in 8.9% of cases and correlated with the presence of moderate transient dysfunction of gas exchange (P=0.001). Severe transient dysfunction of gas exchange was associated with patients who had renal replacement therapy (P=0.0005), hemotherapy (P=0.0001), enteral nutrition (P=0.0012), or cardiac arrhythmia (P=0.0451). CONCLUSION: Preoperative hypertension and cardiogenic shock were associated with the occurrence of postoperative transient dysfunction of gas exchange. The preoperative risk factors included hypertension, cardiogenic shock, and diabetes. Postoperatively, pneumonia, ventilator-associated pneumonia, renal replacement therapy, hemotherapy, and cardiac arrhythmia were associated with the appearance of some degree of transient dysfunction of gas exchange, which was a risk factor for reintubation, pneumonia, ventilator-associated pneumonia, and renal replacement therapy in the postoperative period of cardiac surgery and cardiac procedures.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Troca Gasosa Pulmonar/fisiologia , Doenças Respiratórias/etiologia , Doenças Respiratórias/fisiopatologia , Adulto , Idoso , Complicações do Diabetes , Métodos Epidemiológicos , Feminino , Humanos , Hipertensão/complicações , Unidades de Terapia Intensiva , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Síndrome do Desconforto Respiratório/etiologia , Índice de Gravidade de Doença , Choque Cardiogênico/complicações , Fatores de Tempo
8.
Rev. bras. cir. cardiovasc ; 30(1): 24-32, Jan-Mar/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-742904

RESUMO

Objective: A retrospective cohort study was preformed aiming to verify the presence of transient dysfunction of gas exchange in the postoperative period of cardiac surgery and determine if this disorder is linked to cardiorespiratory events. Methods: We included 942 consecutive patients undergoing cardiac surgery and cardiac procedures who were referred to the Intensive Care Unit between June 2007 and November 2011. Results: Fifteen patients had acute respiratory distress syndrome (2%), 199 (27.75%) had mild transient dysfunction of gas exchange, 402 (56.1%) had moderate transient dysfunction of gas exchange, and 39 (5.4%) had severe transient dysfunction of gas exchange. Hypertension and cardiogenic shock were associated with the emergence of moderate transient dysfunction of gas exchange postoperatively (P=0.02 and P=0.019, respectively) and were risk factors for this dysfunction (P=0.0023 and P=0.0017, respectively). Diabetes mellitus was also a risk factor for transient dysfunction of gas exchange (P=0.03). Pneumonia was present in 8.9% of cases and correlated with the presence of moderate transient dysfunction of gas exchange (P=0.001). Severe transient dysfunction of gas exchange was associated with patients who had renal replacement therapy (P=0.0005), hemotherapy (P=0.0001), enteral nutrition (P=0.0012), or cardiac arrhythmia (P=0.0451). Conclusion: Preoperative hypertension and cardiogenic shock were associated with the occurrence of postoperative transient dysfunction of gas exchange. The preoperative risk factors included hypertension, cardiogenic shock, and diabetes. Postoperatively, pneumonia, ventilator-associated pneumonia, renal replacement therapy, hemotherapy, and cardiac arrhythmia were associated with the appearance of some degree of transient dysfunction of gas exchange, which was a risk factor for reintubation, pneumonia, ventilator-associated pneumonia, and renal replacement therapy in the postoperative period ...


Objetivo: Estudo de coorte retrospectivo com objetivo de verificar a presença de disfunção transitória da troca gasosa no pós-operatório de cirurgia cardíaca e determinar se esse transtorno está relacionado a eventos cardiorrespiratórios. Métodos: Foram incluídos 942 pacientes consecutivos submetidos à cirurgia cardíaca e procedimentos cardíacos, encaminhados para a Unidade de Terapia Intensiva, entre junho de 2007 e novembro de 2011. Resultados: A síndrome do desconforto respiratório agudo foi observada em 15 (2%) pacientes, 199 (27,75%) pacientes apresentaram disfunção transitória da troca gasosa leve, disfunção transitória da troca gasosa moderada foi observada em 402 (56,1%) pacientes e disfunção transitória da troca gasosa grave em 39 (5,4%). A presença de hipertensão arterial sistêmica e choque cardiogênico foi associada ao surgimento de disfunção transitória da troca gasosa moderada no período pós-operatório (P=0,02 e P=0,019, respectivamente) e foram considerados fatores de risco para essa disfunção (P=0,0023 e P=0,0017, respectivamente). A presença de diabetes mellitus também foi considerada um fator de risco para disfunção transitória da troca gasosa (P=0,03). Houve correlação entre a presença de pneumonia e a presença de disfunção transitória da troca gasosa moderada em 8,9% dos casos (P=0,001). A presença de disfunção transitória da troca gasosa grave foi associada a pacientes que necessitaram de hemodiálise (P=0,0005), hemoterapia (P=0,0001), nutrição enteral (P=0,0012), ou arritmia cardíaca (P=0,0451). Conclusão: A presença de hipertensão arterial sistêmica pré-operatória e choque cardiogênico foi associada à ocorrência de disfunção transitória da troca gasosa pós-operatória. Os fatores de risco pré-operatórios foram hipertensão arterial sistêmica, choque cardiogênico e diabetes. No pós-operatório, pneumonia, pneumonia associada à ventilação, hemodiálise, hemoterapia e arritmia cardíaca foram associadas com certo grau de ...


Assuntos
Animais , Humanos , Ratos , Oxirredutases do Álcool/metabolismo , Células Endoteliais/metabolismo , NAD(P)H Desidrogenase (Quinona)/metabolismo , Fenantrenos/metabolismo , Aldeído Redutase , Fator de Ligação a CCAAT/metabolismo , Caspases/metabolismo , Retículo Endoplasmático/metabolismo , Leupeptinas/farmacologia , Oxirredução , Estresse Oxidativo , Poli(ADP-Ribose) Polimerases/metabolismo , Espécies Reativas de Oxigênio/metabolismo
9.
Rev Bras Cir Cardiovasc ; 26(3): 404-12, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22086577

RESUMO

OBJECTIVES: To evaluate plasmatic arginine vasopressin (AVP) levels in patients undergoing scheduled conventional abdominal aortic aneurysm (AAA) repair. METHODS: Plasmatic AVP concentrations were measured by radioimmunoassay in 22 non-consecutive adult patients undergoing infra-renal AAA repair. They were under combined general and epidural anesthesia at the following time frames: 1--pre-operative (T0); 2--2h (T1) and 6h (T2) after the surgical procedure; 3--in the morning at the first (T3), second (T4) and third (T5) post-operative days. Some clinical and laboratory variables were also recorded. RESULTS: The mean age of patients was 68 ± 10 years; 17 were males. Plasmatic AVP (mean ± SD; pg/mL) was within the normal range at T0 (1.4 ± 0.7; baseline), increasing significantly at T1 (62.6 ± 62.9; P<0.001) and at T2 (31.5 ± 49.7; P<0.001), with a progressive fall, returning to basal levels at T5 (2.1 ± 3.8; P = NS). Positive and statistically significant correlations were found between AVP and glycemia, serum lactate and white blood cells counts, but not with systemic arterial pressure or plasma osmolarity during the postoperative period. CONCLUSIONS: Considering that no correlations were found between AVP levels and hemodynamic or plasmatic osmolarity variations in AAA repair, it seems that stress response is mainly secondary to noxious stimulation mediated by the autonomic nervous system that is not completely blocked by anesthetics.


Assuntos
Anestesia/métodos , Aneurisma da Aorta Abdominal/sangue , Aneurisma da Aorta Abdominal/cirurgia , Arginina Vasopressina/sangue , Estresse Fisiológico/efeitos dos fármacos , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Aneurisma da Aorta Abdominal/fisiopatologia , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Fatores de Tempo
10.
Rev. bras. cir. cardiovasc ; 26(3): 404-412, jul.-set. 2011.
Artigo em Inglês | LILACS | ID: lil-624522

RESUMO

OBJECTIVES: To evaluate plasmatic arginine vasopressin (AVP) levels in patients undergoing scheduled conventional abdominal aortic aneurysm (AAA) repair. METHODS: Plasmatic AVP concentrations were measured by radioimmunoassay in 22 non-consecutive adult patients undergoing infra-renal AAA repair. They were under combined general and epidural anesthesia at the following time frames: 1 - pre-operative (T0); 2 - 2h (T1) and 6h (T2) after the surgical procedure; 3 - in the morning at the first (T3), second (T4) and third (T5) post-operative days. Some clinical and laboratory variables were also recorded. RESULTS: The mean age of patients was 68±10 years; 17 were males. Plasmatic AVP (mean±SD; pg/mL) was within the normal range at T0 (1.4±0.7; baseline), increasing significantly at T1 (62.6±62.9; P<0.001) and at T2 (31.5±49.7; P<0.001), with a progressive fall, returning to basal levels at T5 (2.1±3.8; P=NS). Positive and statistically significant correlations were found between AVP and glycemia, serum lactate and white blood cells counts, but not with systemic arterial pressure or plasma osmolarity during the postoperative period. CONCLUSIONS: Considering that no correlations were found between AVP levels and hemodynamic or plasmatic osmolarity variations in AAA repair, it seems that stress response is mainly secondary to noxious stimulation mediated by the autonomic nervous system that is not completely blocked by anesthetics.


OBJETIVOS: Avaliar os níveis plasmáticos de vasopressina (AVP) em pacientes submetidos à correção convencional de aneurisma de aorta abdominal (AAA). MÉTODOS: A AVP plasmática foi mensurada por radioimunoensaio em 22 pacientes não-consecutivos submetidos à correção eletiva de AAA infrarrenal sob anestesia geral + epidural nos seguintes momentos: pré-operatório (T0); 2h (T1) e 6h (T2) após a cirurgia; e nas manhãs do primeiro (T3), segundo (T4) e terceiro (T5) dia pós-operatório (PO). Variáveis clínicas e laboratoriais de interesse também foram anotadas. RESULTADOS: A média de idade dos pacientes foi de 68±10 anos, sendo 17 homens. A AVP plasmática (média±DP; pg/ mL) estava dentro de limites normais no T0 (1,4±0,7; basal), aumentando no T1 (62,6±62,9; P<0,001) e no T2 (31,5±49,7; P<0,001), e retornando aos valores basais no T5 (2,1±3,8; P=NS). Correlações positivas e significativas foram encontradas entre a AVP e glicemia, lactato sérico e leucócitos sanguíneos, mas não com a pressão arterial sistêmica ou com a osmolaridade plasmática no PO. CONCLUSÕES: Na cirurgia de reparação de AAA, considerando que nenhuma correlação foi encontrada entre os níveis de AVP e variações hemodinâmicas ou da osmolaridade plasmática, este achado sugere que a resposta ao estresse é predominantemente secundária aos estímulos dolorosos mediados pela parte autônoma do sistema nervoso, não completamente bloqueados pelos anestésicos.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anestesia/métodos , Aneurisma da Aorta Abdominal/sangue , Aneurisma da Aorta Abdominal/cirurgia , Arginina Vasopressina/sangue , Estresse Fisiológico/efeitos dos fármacos , Análise de Variância , Aneurisma da Aorta Abdominal/fisiopatologia , Biomarcadores/sangue , Período Pós-Operatório , Estudos Prospectivos , Fatores de Tempo
11.
Fisioter. pesqui ; 17(4): 337-341, out.-dez. 2010. tab, graf
Artigo em Português | LILACS | ID: lil-587977

RESUMO

A mensuração da função respiratória oferece informações essenciais para caracterizar anormalidades pulmonares. A pressão hidrostática da água atua no tórax submerso de diversas formas, causando alterações no sistema respiratório. O objetivo deste estudo foi analisar comparativamente variáveis que avaliam a função respiratória - volume minuto (Vmin), volume corrente (Vc), capacidade vital (Cvital) e frequência respiratória (FR) - de voluntárias no solo e com o tórax submerso em piscina terapêutica aquecida. A função respiratória de 30 voluntárias saudáveis (20,9±2,1 anos; 1,64±0,07 m; 58,8±9,2 kg; índice de massa corporal 21,78±2,63 kg/m2) foi avaliada por meio de ventilômetro em solo e aos 1 e 20 minutos de imersão, com água ao nível dos ombros, em posição sentada. Após 20 minutos de imersão, foi registrado aumento estatisticamente significativo no Vmin (p=0,015) e Vc (p=0,027); e uma redução estatisticamente significativa (p=0,016) na Cvital 1 minuto após imersão, em relação aos valores obtidos em solo. O maior tempo de imersão alterou assim os valores obtidos em solo, com exceção da Cvital, que sofreu alteração significativa desde o primeiro minuto de imersão. Não foram encontradas diferenças significativas entre os valores obtidos após 1 e 20 minutos na água. O estudo permite concluir que a imersão do tórax em piscina aquecida provocou aumento no Vmin e Vc e diminuição na Cvital de voluntárias saudáveis.


Measuring respiratory function provides essential information to assess pulmonary changes. Effects of water hydrostatic pressure on the submerged chest cause changes in the respiratory system. The purpose here was to compare respiratory function variables - minute volume (MV), tidal volume (TV), vital capacity (Vitalc), and respiratory rate (RR) - on the ground and with chest submerged in water. Respiratory function of 30 healthy female volunteers (mean age 20.93 ± 2.11; weight 58.8±9.2 kg; body mass index 21.78±2.63 kg/m2) was assessed by spirometry on the ground, and 1 and 20 minutes after immersion in warm water at shoulder level in the sitting position. As compared to ground levels, statistically significant increases were found in MV (p=0.015) and TV (p=0.027) 20 minutes after immersion, as well as a significant decrease (p=0.016) in Vitalc one minute after immersion. Longer time immersion has thus altered values obtained on ground, except for Vitalc, which showed significant reduction on the first minute after chest immersion. Comparison between variable values obtained 1 and 20 minutes in water showed no significant difference. It may thus be said that chest submersion in warm water caused an increase in MV and VT and a decrease in Vitalc of healthy subjects.


Assuntos
Humanos , Feminino , Adolescente , Adulto , Imersão , Medidas de Volume Pulmonar , Testes de Função Respiratória , Capacidade Vital
12.
Rev. bras. ter. intensiva ; 22(4): 375-383, out.-dez. 2010.
Artigo em Português | LILACS | ID: lil-572694

RESUMO

A insuficiência respiratória após a cirurgia cardíaca com utilização da circulação extracorpórea pode ser resultante de inúmeros fatores relacionados às condições do sistema respiratório no pré, intra e pós-operatório. A finalidade desta revisão é discutir alguns dos fatores relacionados à lesão pulmonar observada no período pós-operatório de cirurgia cardíaca e quais os recursos ventilatórios têm sido propostos para minimizar e/ou tratar a hipoxemia dos pacientes.


Respiratory failure after cardiopulmonary bypass heart surgery can result from many pre-, intra- or postoperative respiratory system-related factors. This review was aimed to discuss some factors related to acute lung injury observed during the postoperative period of cardiac surgery and the mechanical ventilation modalities which should be considered to prevent hypoxemia.

13.
Arq. bras. ciênc. saúde ; 35(3)set.-dez. 2010.
Artigo em Português | LILACS | ID: lil-573363

RESUMO

Introdução: A pleurotomia durante a cirurgia cardíaca pode danificar a função respiratória durante o período pós-operatório, podendo interferir no tempo de internação hospitalar. Objetivo: Comparar os dias de internação hospitalar em pacientes submetidos à cirurgia de revascularização do miocárdio com e sem realização de pleurotomia. Métodos: A pesquisa foi composta por 20 pacientes submetidos à cirurgia de revascularização do miocárdio com circulação extracorpórea, sendo divididos em dois grupos: G1 ? pacientes que realizaram pleurotomia (n=10) e G2 ? pacientes que não realizaram pleurotomia (n=10). Resultados: Os resultados mostraram que os pacientes do grupo G1 quando comparados aos pacientes do grupo G2 obtiveram média de internação semelhante (7,2±0,78 versus 6,8±0,42 dias). Conclusão: Não houve diferença significativa no tempo de internação entre os grupos de pacientes com e sem pleurotomia.


Introduction: Pleurotomy on cardiac surgery may damage the respiratory function during the postoperative period, and may also interfere on the length of hospital stay. Objective: To compare the length of hospital stay of patients that were submitted to myocardial revascularization surgery with or without pleurotomy. Methods: This research was composed by 20 patients submitted to myocardial revascularization surgery with cardiopulmonary bypass, and they were divided into two groups: G1 ? patients submitted to pleurotomy (n=10) e G2 ? patients not submitted to pleurotomy (n=10). Results: The results showed that the G1 patients when compared to G2 patients obtained similar average length of hospital stay (7.2±0.78 versus 6.8±0.42 days). Conclusion: There was no statistical difference regarding the length of hospital stay between the groups.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Circulação Extracorpórea , Revascularização Miocárdica , Pleura/cirurgia , Tempo de Internação/estatística & dados numéricos
14.
Rev Bras Ter Intensiva ; 22(4): 375-83, 2010 Dec.
Artigo em Inglês, Português | MEDLINE | ID: mdl-25302515

RESUMO

Respiratory failure after cardiopulmonary bypass heart surgery can result from many pre-, intra- or postoperative respiratory system-related factors. This review was aimed to discuss some factors related to acute lung injury observed during the postoperative period of cardiac surgery and the mechanical ventilation modalities which should be considered to prevent hypoxemia.

15.
Fisioter. pesqui ; 17(1): 30-33, 2010. tab
Artigo em Português | LILACS | ID: lil-556392

RESUMO

Testes de função pulmonar são usados para determinar a gravidade, as conseqüências funcionais e o progresso de disfunções pulmonares e neuromusculares. As variações metodológicas com o bocal e a máscara facial e a cooperação do paciente podem interferir no desempenho das manobras e afetar as medidas. O objetivo deste estudo foi comparar os valores de volumes pulmonares (volume corrente [Vc], volume-minuto [Vm]), freqüência respiratória (FR) e capacidade vital (CV) em indivíduos saudáveis quando avaliados por meio do bocal e da máscara facial. Participaram do estudo 60 voluntários saudáveis, 14 homens e 46 mulheres, com média de idade de 22,9±7,1 anos. Para a avaliação com bocal, utilizou-se uma peça semirrígida descartável e clipe nasal; a máscara usada foi facial plástica com borda pneumática inflável. As medidas obtidas foram comparadas estatisticamente (nível de significância 5%). Os valores obtidos com o bocal e com a máscara facial foram, respectivamente: FR, 15 rpm x 13 rpm (p<0,01); Vm, 14,87 l/min x 10,02 l/min (p<0,01); Vc, 0,93 l x 0,8 l (p<0,01); CV, 3,85 l x 3,52 l (p<0,01). Os valores de volumes pulmonares e capacidade vital mostraram-se pois significativamente inferiores quando avaliados com a máscara facial em comparação ao bocal...


Respiratory function tests are used to determinate severity, functional consequences and progress of pulmonary and neuromotor dysfunctions. Methodological variations – by means of a mouthpiece or a facemask – and patient’s cooperation may interfere in manoeuvre performance and affect measures. The aim of this study was to compare lung volume values (tidal volume [VT] and minute volume [Vm]), respiratory rate (RR), and vital capacity (VC) in healthy individuals when assessed by using a mouthpiece and a facemask. A total of 60 healthy subjects (14 men and 46 women), mean aged 22.86±7.14 years, were evaluated. Items used were a disposable, semi-rigid mouthpiece, with a nose clip, and a plastic facemask with pneumatic inflatable sealing. Measures obtained were statistically compared, with significance level set at 5%. Mean values obtained with the mouthpiece and the facemask were, respectively: RR, 15 rpm x 13 rpm (p<0.01); Vm, 14.87 l/min x 10.02 l/min (p<0.01); VT, 0.93 l x 0.8 l (p<0.01); and VC, 3.85 l x 3.52 l (p<0.01). Lung volumes and vital capacity values were thus shown to be significantly lower when assessed by means of a facemask than with a mouthpiece...


Assuntos
Humanos , Masculino , Feminino , Medidas de Volume Pulmonar , Testes Respiratórios/instrumentação , Capacidade Vital
16.
Rev. bras. cir. cardiovasc ; 24(4): 490-496, out.-dez. 2009. graf, tab
Artigo em Inglês, Português | LILACS | ID: lil-540751

RESUMO

Objetivo: A dor no pós-operatório de cirurgia cardíaca é frequente. Poucos relatos existem sobre a sua relação com a função respiratória e o local mais frequentemente relatado. O objetivo é avaliar a intensidade e a localização da dor durante o período de internação e suas repercussões na função respiratória de pacientes submetidos à cirurgia cardíaca eletiva. Métodos: A função respiratória (volumes pulmonares, força muscular respiratória e pico de fluxo expiratório) foi avaliada nos períodos pré-operatório e pós-operatório (1º, 3º e 5º dia), utilizando os equipamentos ventilômetro, manovacuômetro e medidor de pico de fluxo expiratório. Para mensuração da dor utilizamos a escala visual analógica de dor. Resultados: O local com maior frequência de dor referida foi o esterno (50 por cento dos pacientes) e sua intensidade foi maior no primeiro dia de pós-operatório (8,32 na escala visual analógica). Em todas as variáveis analisadas houve piora dos valores em relação aos obtidos no pré-operatório (P < 0,05) e não observamos o retorno aos valores pré-operatórios até o quinto dia de pós-operatório em todas as variáveis observadas, com exceção da frequência respiratória. Foi observada correlação negativa entre a dor e a pressão inspiratória máxima no primeiro dia de pós-operatório (P = 0,019). Conclusão: A dor pós-operatória diminuiu a função respiratória nos pacientes avaliados, prejudicando a realização de inspirações profundas, principalmente no primeiro dia de pós-operatório.


Objective: The post operative pain after open heart surgeries had been often reported. Meager reports about respiratory function and pain correlation had been reported. The aim of this article is to assess the pain intensity and location during hospital admittance and its effect on pulmonary function in patients underwent elective cardiac surgery. Methods: Pulmonary function (lung volumes, respiratory pressures and peak expiratory flow) was assessed at the preoperative and post-operative time (1, 3 and 5 days) by ventilometer, manovacuometer and peak flow meter measurements. The assessment of pain intensity was carried out with a visual analogue scale for pain. Results: The majority of pain site was on sternotomy incision (50 percent of patients) and the intensity was higher at the first postoperative day (8.32 by visual scale measurement). All pulmonary variables decreased on post-operative time when compared to baseline values. All respiratory variables remained lower than to pre-operative time at fifth postoperative time (P > 0.05), with exception for respiratory rate. The pain and maximal inspiratory pressure showed a negative correlation at the first postoperative day (P = 0.019). Conclusion: Postoperative pain decreased lung function in patients precluding deep inspirations, in special, at the first post-operative day.


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Cardíacos , Pulmão/fisiopatologia , Dor Pós-Operatória/fisiopatologia , Respiração , Distribuição de Qui-Quadrado , Tempo de Internação , Medição da Dor , Estatísticas não Paramétricas , Fatores de Tempo
17.
Rev Bras Cir Cardiovasc ; 24(4): 490-6, 2009.
Artigo em Inglês, Português | MEDLINE | ID: mdl-20305922

RESUMO

OBJECTIVE: The post operative pain after open heart surgeries had been often reported. Meager reports about respiratory function and pain correlation had been reported. The aim of this article is to assess the pain intensity and location during hospital admittance and its effect on pulmonary function in patients underwent elective cardiac surgery. METHODS: Pulmonary function (lung volumes, respiratory pressures and peak expiratory flow) was assessed at the preoperative and post-operative time (1, 3 and 5 days) by ventilometer, manovacuometer and peak flow meter measurements. The assessment of pain intensity was carried out with a visual analogue scale for pain. RESULTS: The majority of pain site was on sternotomy incision (50% of patients) and the intensity was higher at the first postoperative day (8.32 by visual scale measurement). All pulmonary variables decreased on post-operative time when compared to baseline values. All respiratory variables remained lower than to pre-operative time at fifth postoperative time (P > 0.05), with exception for respiratory rate. The pain and maximal inspiratory pressure showed a negative correlation at the first postoperative day (P = 0.019). CONCLUSION: Postoperative pain decreased lung function in patients precluding deep inspirations, in special, at the first post-operative day.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Pulmão/fisiopatologia , Dor Pós-Operatória/fisiopatologia , Respiração , Distribuição de Qui-Quadrado , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Medição da Dor , Estatísticas não Paramétricas , Fatores de Tempo
18.
Rev Bras Cir Cardiovasc ; 23(2): 209-15, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18820784

RESUMO

OBJECTIVE: To compare postoperative (PO) pulmonary gas exchange indexes in patients submitted to myocardial revascularization (MR) with or without the application of continuous positive airway pressure (CPAP) during cardiopulmonary bypass (CPB). METHODS: Thirty adult patients submitted to MR with CPB between March and September 2005 were randomly allocated to two groups: CPAP (n=15), patients that received CPAP at 10 cm H2O during CPB, and control (n=15), patients that didn't receive CPAP. PaO(2)/FiO2 and P(A-a)O2 were analyzed at four moments: Pre (just before CPB, with FiO2=1.0 ); Post (30 min post-CPB, with FiO2=1.0); immediate PO period (12h post-surgery, with FiO2=0.4 by using a Venturi(R) facial mask) and first PO day (24h post-surgery, with FiO2=0.5 by a facial mask). RESULTS: PaO2/FiO2 and P(A-a)O2 tend to get significantly worst as time elapsed during the postoperative period in both groups, but no differences were observed between them at any moment. When PaO2/FiO2 was subdivided into three categories, a greater prevalence of patients with values between 200 mmHg and 300 mmHg were observed in CPAP group only at moment Post (30 min post-CPB; p = 0.02). CONCLUSION: CPAP at 10 cm H2O administered during CPB, although had lightly improved PaO2/FiO2 at 30 minutes post-CPB, had no significant sustained effect on postoperative pulmonary gas exchange. We concluded that in patients submitted to MR, application of 10 cmH2O CPAP does not improve postoperative pulmonary gas exchange.


Assuntos
Ponte Cardiopulmonar , Pressão Positiva Contínua nas Vias Aéreas/métodos , Revascularização Miocárdica , Troca Gasosa Pulmonar/fisiologia , Adolescente , Adulto , Análise de Variância , Distribuição de Qui-Quadrado , Feminino , Humanos , Masculino , Período Pós-Operatório , Fatores de Tempo , Adulto Jovem
19.
Rev. bras. cir. cardiovasc ; 23(2): 209-215, abr.-jun. 2008. ilus, tab, graf
Artigo em Inglês | LILACS | ID: lil-492973

RESUMO

OBJECTIVE: To compare postoperative (PO) pulmonary gas exchange indexes in patients submitted to myocardial revascularization (MR) with or without the application of continuous positive airway pressure (CPAP) during cardiopulmonary bypass (CPB). METHODS: Thirty adult patients submitted to MR with CPB between March and September 2005 were randomly allocated to two groups: CPAP (n=15), patients that received CPAP at 10 cmH2O during CPB, and control (n=15), patients that didn't receive CPAP. PaO²/FiO2 and P(A-a)O2 were analyzed at four moments: Pre (just before CPB, with FiO2=1.0 ); Post (30min post-CPB, with FiO2=1.0); immediate PO period (12h post-surgery, with FiO2=0.4 by using a Venturi® facial mask) and first PO day (24h post-surgery, with FiO2=0.5 by a facial mask). RESULTS: PaO2/FiO2 and P(A-a)O2 tend to get significantly worst as time elapsed during the postoperative period in both groups, but no differences were observed between them at any moment. When PaO2/FiO2 was subdivided into three categories, a greater prevalence of patients with values between 200 mmHg and 300mmHg were observed in CPAP group only at moment Post (30min post-CPB; p = 0.02). CONCLUSION: CPAP at 10cmH2O administered during CPB, although had lightly improved PaO2/FiO2 at 30 minutes post-CPB, had no significant sustained effect on postoperative pulmonary gas exchange. We concluded that in patients submitted to MR, application of 10 cmH2O CPAP does not improve postoperative pulmonary gas exchange.


OBJETIVO: Comparar os índices de trocas gasosas no pós-operatório de pacientes submetidos a revascularização do miocárdio (RM) que receberam ou não pressão positiva contínua nas vias aéreas (CPAP) durante a circulação extracorpórea (CEC). MÉTODOS: Trinta pacientes adultos submetidos a RM com CEC no período de março a setembro de 2005 foram alocados aleatoriamente em dois grupos: CPAP (n=15), pacientes que utilizaram CPAP a 10 cmH2O durante a CEC, e controle (n=15), pacientes que não utilizaram CPAP. Foram analisados a PaO2/FiO2 e o P(A-a)O2 em quatro momentos: Pré (logo antes da CEC, com FiO2 = 1,0); Pós (30min pós-CEC, com FiO2 = 1,0); PO imediato (12h após a cirurgia, com FiO2 = 0,4, utilizando máscara facial) e 1º PO (24 horas após a cirurgia, com FiO2 = 0,5, utilizando máscara facial). RESULTADOS: A PaO2/FiO2 e o P(A-a)O2 mostraram piora significativa no decorrer do tempo dentro de cada grupo, porém sem diferenças significativas entre os grupos em nenhum momento. Quando a PaO2/FiO2 foi subdividida em três categorias, foi observada maior prevalência de pacientes do grupo CPAP com valores entre 200 mmHg e 300 mmHg (p=0,02) apenas no momento Pós (30min pós-CEC). CONCLUSÃO: O uso de CPAP de 10 cmH2O durante a CEC, muito embora tenha resultado em melhores valores na PaO2/FiO2 30 minutos pós-CEC, não resultou em benefícios duradouros nas trocas gasosas durante o PO. Nós concluímos que, em pacientes submetidos a RM, a aplicação de CPAP 10 cmH2O não melhora significativamente as trocas gasosas pulmonares no pós-operatório.


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Ponte Cardiopulmonar , Pressão Positiva Contínua nas Vias Aéreas/métodos , Revascularização Miocárdica , Troca Gasosa Pulmonar/fisiologia , Análise de Variância , Distribuição de Qui-Quadrado , Período Pós-Operatório , Fatores de Tempo , Adulto Jovem
20.
Rev. bras. ter. intensiva ; 19(3): 331-336, jul.-set. 2007. ilus, tab
Artigo em Português | LILACS | ID: lil-470944

RESUMO

JUSTIFICATIVA E OBJETIVOS: Esta pesquisa justifica-se na necessidade de maior conhecimento a respeito das técnicas de desmame ventilatório utilizadas em pacientes sob ventilação mecânica prolongada. O objetivo deste estudo foi comparar a obtenção do índice de respiração rápida e superficial (IRRS) nas modalidades PSV de 10 cmH2O e PEEP de 5 cmH2O (PSV10); CPAP de 5 cmH2O (CPAP5) e em ventilação espontânea (ESP), correlacionando com sucesso ou insucesso na retirada da ventilação mecânica (VM). MÉTODO: Estudo prospectivo incluindo 54 pacientes em VM há mais de 48 horas, submetidos ao IRRS em três modos ventilatórios: PSV10, CPAP5 e ESP nos momentos pré e pós-nebulização, utilizando tubo-T. Os pacientes foram retirados da VM quando o IRRS era < 105. RESULTADOS: Não houve diferença estatisticamente significativa entre os valores do IRRS obtidos nos momentos pré e pós-nebulização. Houve diferença estatística significativa dos valores do IRRS entre CPAP5 e PSV10 (p = 0,008) e entre a modalidade ESP e PSV10 (p = 0,01) no momento pré-nebulização e dos valores do IRRS obtidos entre CPAP5 e PSV10 (p = 0,01) no momento pós-nebulização. CONCLUSÕES: Neste estudo pode-se observar que o valor do IRRS foi superestimado quando obtido na modalidade PSV10. Foi constatado também que não houve necessidade de nebulização de 30 minutos antes da extubação traqueal quando o desmame é realizado com a técnica de redução gradativa da PSV. Este estudo sugeriu que o IRRS foi capaz de prever o sucesso do desmame; entretanto, incapaz de determinar o insucesso quando seu valor fosse < 105. Recomenda-se que o IRRS seja analisado em associação com outros parâmetros preditivos de desmame.


BACKGROUND AND OBJECTIVES: To compare the attainment of the rapid shallow breathing index (IRRS) in modalities PSV 10 cmH2O and PEEP 5 cmH2O (PSV10), CPAP 5 cmH2O (CPAP5) and spontaneous breathing (SB), correlating them with success on failure in the withdrawal of mechanical ventilation (MV). METHODS: Prospective study including 54 patients in MV > 48 hours, submitted to the IRRS in three ventilatory modalities: PSV10, CPAP5 and SB at the moments before and after T-tube spontaneous breathing. The patients were removed from MV when IRRS was < 105. RESULTS: There wasn't statistically significant difference between IRRS values at the moments before and after T-tube SB. There was statistically significant difference IRRS value between the modalities CPAP5 and PSV10 (p = 0.008), and between the modalities SB and PSV10 (p = 0.01) at the moment before T-Tube SB and of IRRS value, gotten between CPAP5 and PSV10 (p = 0.01) at the moment after T-tube SB. CONCLUSIONS: From this sample, it can be observed that IRRS values are overestimated when gotten in modality PSV10. It was also evidenced that there is no need of a 30 min T-tube SB before extubation, when the weaning is performed with the technique of gradual reduction of PSV. This study suggested that IRRS is able to predict weaning success; however it is not able to determine failure when it was < 105. It is recommended that IRRS must be analyzed in association with other predictive weaning parameters.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Desmame do Respirador/métodos , Respiração Artificial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...